August 25, 2009 |
The new version of PC-3000 for Windows 4.3x with Data Extractor UDMA 4.10.x |
Samsung
- The possibility to edit Burn-script commands in hex-format is added*
- F2_EG family is added
- The speed of writing modules is increased for F1_3D family
- S.M.A.R.T. attributes description is added
- Test of recovery T-List on S-List is added
- Test of recovery T-List on S-List and D-LIST is added
- PARAGON family is added
- Autodetection of MANGO family models is appended
- F1_3D family is appended
- The possibility of file loading through terminal in menu Work with BURN is appended
Seagate F3
- Head map build function through interface ATA for Data Extractor is appended
- Families Momentus 5400.5, 5400 are appended into the list of supported families
- The following user commands are appended:
-
G-List -> P-List transfer
Reserve Track Slip List scan
User Track Slip List scan
P-List scan
Alt-list scan
Translator regenerator
- Selection the list of supported families is appended in utility menu
Seagate
- New possibilities of utility and DE interaction are appended. Now the following actions are available:
- 1. the second variant of solving "pending problem"
2. SysSect writing blocking while HDD working
3. modification LBA->PCHS through ATA interface
4. soling the problem of impossibility of HDD launching in ATA mode as a result of impossibility of overlay loading ovl1
WD Marvell
- Specialized head map editing mode is added (without ROM changing)
- Algorithm of calculating control sum of head map
- We added the options to clear the translator and the defect lists at SelfTest launching
- While track writing the physical heads are selected and writing is made on selected physical heads, but in the protocol logical numbers of heads were written. This error is corrected.
- Module catalogue for HDD Zeus interpretation and reading error is repaired
- For all ROYL families module catalogue interpretation algorithm is modified
- The possibility of extraction files/documents database on any head 0...7 is appended into dialogues track selection for writing
- In data scan mode from ROM the output information about Microjogs is appended
- Plugin for Micrologs editing is appended (is available while editing module 47)
- Heads map editing mode is appended in RAM
- Mars family support is appended
- Pinclite family support is appended
- For Sabre family module OD ROM calling error is repaired (Sabre does not have module OD)
- Module OD reading error message while LDR loading for non ROYL HDD is removed
- Profile folder name and database for Denali family is repaired
Maxtor
- New improvements for Grizzly-like models are added
- Translator recalculation is added
HITACHI-IBM
- "Clear S.M.A.R.T. " algorithm switch S.M.A.R.T. on before clearing it
- NV-RAM fitting algorithm for HTS5425 family has considered the peculiarity of service information cylinder numbers table building on heads in NV-RAM
- Parameters for working with ROM for HTS5416J9 and HTS5425K9 families are modified
- While working with G-List in 2.5' HDD table the format is corrected
- Self Test start algorithm is corrected with the purpose of giving the opportunity for user to launch testing HDD for separate power module
Toshiba
- Full - function support of 34GSX, 35GSS, 37GSX SATA families is appended
Fujitsu
- Support of some HDD from MHY family is added (unlocking password on terminal, head map building for DE)
- Modified algorithm for password unlocking via terminal is used in MHV, MHW, MHX, MHY families
- Configurational settings for MPA, MPB, MPC, MPD families are repaired
Data Extractor
- Algorithm of analysis of NTFS partition data is improved
- New possibility to export data using maps is added
- Now the correct operations are done when there is not enough space in the disk at copy creation to image files
- GREP search is optimized, so search is now several times quicker
- Quick-commands toolbar now has a "Sleep" button
- We added the possibility to save files and folders without limiting the length of the path
- New option that enables/disables autoswitch of "Map" tab to "Log" after 5 mins of copying was added to task parameters
- The possibility to make HDD Sleep when it is not active is appended (in task settings)
- Copying rate while working with regular connected HDDs is increased on 30% due to asynchronous writing implementation
- Now there is a comment to it (if exists) while chain reading
- Data import in the object map and saving rate is increased considerably
- Selected chains removing rate is increased considerably
- Map selected chains removing rate is increased considerably
- While modification chain's attribute in the object map it is possible to put them down to CLIPBOARD
- While modification chain start in object map the length is modified
- The possibility to add selected folders and files is appended into the explorer
- Working with memory while generation or using map with the great number of chains and comments to them is enhanced (was tested up to 1 mln)
- Head number is appended in object map into Hint
- In object map while data saving/importing the catalogue is installed on default - task catalogue
NTFS
- Structures logical analysis control is appended in case of physical damages
- While forming used/unused map the $Bitmap reading is now performed by means of blocks by 255 sectors (earlier it was performed by 1 sector)
HFS+
- While writing dissection the structure integrity control is enhanced
- ResourceFork saving to file name.ext.rsc is appended
- While forming used/unused map the reading is now performed by means of blocks by 255 sectors (earlier it was performed by 1 sector)
Now it is not performed by file system initialization, only on demand for corresponding map forming - BadBlockFile map forming is appended
Database client
- "Database information" mode is appended. It is available through "Database access parameters" form
- We developed the utility of recovering the absent attributes of WD Marvell utility resource profile. Owing to resources created by earlier utility versions were not found while resource searching
- After downloading update "critical failure" error is repaired (after installing Setup there was no error)
PC-3000 Core
- Fallout lines problem in terminal is solved
- At the instance of our users (ATA 0/1) popping-up diagnostic port selection list is shifted closer to power control button
Universal utility
- Fault indicator error is repaired
* - All bold changes are done after the release of beta version.